ZSN1 regulator of outlet pressure p2
Basic model of self-acting regulator. Controls the constant preset pressure on the output side.
Nominal diameter
- DN 15 – DN 100
- 1/2“ – 4“
Nominal pressure
- PN 10 – 40
- ANSI 150 – 300
Construction
- self-operated regulator of outlet pressure p2 – type ZSN 1
Flow characteristic, Kvs values
- proportional
- 1 – 125 [m3/h]
Shut off tightness (IEC 60 534 – 4)
- Class IV - standard, metal seat
- Class V - possible for metal seat
Body material
- grey cast iron, ductile iron, carbon steel, stainless steel according to EN, DIN or ASTM
Setting range [kPa]
- 40 – 160
- 100 – 400
- 200 – 800
- 280 – 1 120
Maximal loss of pressure on the valve [MPa]
- 1,2
Maximal pressure in actuator chamber [MPa]
- 2,0
Connection
- flange